2 printer/serial output setup, 1 control modes, Control modes – Rice Lake MSI-3460 Challenger 3 User Manual

Page 45

Advertising
background image

RF Remote Display Option 41

7.2 Printer/Serial Output Setup

The RS-232 comm port is capable of outputting tension data. All the weight modes

the RF linked weight device can measure are available in user formatted form. The

control mode programs are what causes the MSI-3460 to print. The modes are:

• When an assigned F-Key is pressed, one transmission of the selected string type

is output.

• On Load- When the tension on the link is stable, one transmission will output.

Then the tension must return to zero to enable another print output.

• Continuous - program the interval in seconds up to 65,535 seconds. Setting the

interval to 0 will set an interval as fast as the system can go.

To disable printing set the control mode to “OFF.”
The MSI-3460comm port settings are independent of the print settings in the

connected MSI-8000. They reside only in the MSI-3460.
Far more complex print/serial strings can be introduced using MSI’s SCCMP setup

program. See SCCMP User Guide for more details.

7.2.1

Control Modes

The user can select four control modes:

1. User - Printing is controlled by the operator pushing the PRINT key (usually

F3).

2. Load - One print output when a stable load is reached. The scale must return to

near zero before another print will occur. Other configurations of “On Load” are

available using the SCCMP program.

3. Continuous - The MSI-8000 will continuously output the data at a rate

controlled by the  (RATE) menu.

4. OFF - Printing is disabled. Power consumption is lower with print off.