4.3 Auto- Off

The Auto-Off feature, when enabled, prolongs the battery life of the scale by turning

POWER off when the scale is not in use. Any time a button is depressed (any button),

or the detected weight is in motion exceeding 5 or 10d, the time limit is reset.

Therefore, the scale will stay on indefinitely if the weight is changing or any button is

pressed at least once. With Auto-Off disabled, the scale will remain on; only pressing

POWER will turn it off (or if the battery is depleted).

1) With the 3460 off, press and hold

the

USER

key, then press the

POWER

key.

...or while the 3460 is on, press

USER

and

POWER

simultaneously.

2) The first item of the Setup Menu

is Func1. Scroll to “A-OFF” with

the

USER

key.

3) To set up the A-Off timing, press

TARE

. The current Auto-Off time

is displayed.

4) Select the Auto Off time by

scrolling through the choices with

the

USER

key.

In this example, we’ll set 60 minutes as
the Auto-Off time.

5) When the desired time is

displayed, press

TARE

. The next

item in the Setup Menu appears.

6) Either press

ZERO

to exit Setup

and store all changes, or
continue to another Setup Menu
item using the

USER

key.

Auto-Off Setup

)YQF



GLVS/

Next Setup Menu Item

TARE

TARE

USER

F

POWER

Hold

USER

F

2II

blinking

USER

F



USER

F

ZERO

Cancel all setup
changes



USER

F



USER

F

blinking

blinking

blinking

blinking

$2))

USER

F

Store and return to

weight display

6WRUH

POWER

Figure 4-3. Auto-Off