Qwuo, 3ulqw 6wuq, 2)) 8v(u – Rice Lake MSI-3460 Challenger 3 User Manual

Page 47: R$g &rqw, Udwh, Printer / output setup

Advertising
background image

1)

With the MSI-3460 on, press the

TARE

key and the

USER

keys

simultaneously.

2)

The LCD shows Print. Press

TARE

.

3)

The sub-menu item StrnG
(String) appears. Press

TARE

.

4)

The current print pode format
number is displayed.

5)

Set up a print format with one or
more digits representing the data
type required for the print output.

In this example, we’ll set the Print format
for a Net, Gross, Tare output with a
carriage return/line feed between each
print output. The number entry required
will be 2349. The 2 is for Net weight,
the 3 for Gross weight, the 4 for Tare
weight, and the 9 inserts a space before
the next print output.

6) Press the

USER

key to scroll

through the digits until the desired
digit is shown, then press

TARE

to enter the digit value. Repeat
for the remaining digits.

7) When the entire number is

displayed press

TARE

. The next

item in the Print menu appears,
Cntrl.

8) Press

TARE

to enter the print

control menu. The last set control
mode will appear.

9) To change the print control mode,

press

USER

.

In this example, we’ll set the print control
mode to continuous.

10) Press

USER

key until the desired

print control mode is shown.

11) When the desired print mode is

shown, push

TARE

to save. The

next print setup item, rAte
appears. If you have set
continuous (cont) as your print
control, proceed to step 12). For
any other Control mode jump to
step 15.

12) Press

TARE

to enter the print

rate number entry screen. The
current print rate appears on the
LCD.

In this example, we’ll set the print rate
to an output rate of once every 2
seconds.

Printer / Output Setup











blinking

blinking

fixed

fixed

fixed

&QWUO

Next Print Menu Item

3ULQW

6WUQ



blinking



fixed



blinking

Example Value



blinking



blinking

2))

2))

8V(U

Function Key Prints

Print is disabled

/R$G

&RQW

Function Key Prints

Print is disabled

UDWH

Next Print Menu Item

1= Current Wt

(Wt-Unit-Mode )

2= Net Wt

(Wt-Unit-Net )

3= Gross Wt

(Wt-Unit-Grs )

4= Tare Wt

(Wt-Unit-Tare )

5= Total Wt

(Wt-Unit-Total )

6= Total Count

(#Samples-TCNT )

7= Current Wt

(no units or mode )

8=

(Reserved)

9= CR-LF (

)

TARE

TARE

TARE

TARE

TARE

TARE

TARE

TARE

TARE

USER

F

USER

F

USER

F

USER

F

USER

F



blinking

Example Value

The number represents the print
interval rate in seconds. Use 0 for the
fastest the MSI-8000 can go (~5 times
per second). To set a once a minute
transmission, set the rate to 60. To

set once per hour, set the rate to 3600, etc. Largest possible
entry is 65535 which is >18 hours.

TARE

USER

F

USER

F

USER

F

USER

F

Press Simultaneously

TARE

USER

F

RF Remote Display Option 43

Figure 7-3. Printer Output Setup