Model-specific data – Rice Lake Secura - Quintix and Practum Series - User Manual User Manual

Page 97

Advertising
background image

97

Specifications

User Manual for Secura, Quintix, Practum

Model-specific Data

Verified Models with Country-specific Type Approval Certificate

Secura

®

Model

224-1x

1

) 124-1x

1

) 513-1x

1

) 313-1x

1

)

213-1x

1

)

5102-1x

1

) 3102-1x

1

) 2102-1x

1

) 1102-1x

1

)

Accuracy class

k

k

K

K

K

K

K

K

K

Type

2

)

SQP-A

SQP-A

SQP-B

SQP-B

SQP-B

SQP-C

SQP-C

SQP-D

SQP-D

Max g

220

120

510

310

210

5.100

3.100

2.100

1.100

Scale interval d

mg

0.1

0.1

1

1

1

10

10

10

10

Verification scale interval e

mg

1

1

10

10

10

100

100

100

100

Min

mg

10

10

20

20

20

500

500

500

500

Tare (subtractive)

< 100% of max. weighing capacity

Minimum sample weight
as per USP, typical

g

0.12

0.12

1.5

1.5

1.5

12

12

12

12

Typical stabilization time

s

2

2

1.5

1.5

1.5

1.5

1.5

1.5

1.5

isoCAL:
– Temperature change
– Time interval


K
h


1.5
4


1.5
4


2
6


2
6


2
6


2
6


2
6


2
6


2
6

Display result
(depending on the set filter level)

s

0.2

0.2

0.1/0.2

0.1/0.2

0.1/0.2

0.1/0.2

0.1/0.2

0.1/0.2

0.1/0.2

Weighing pan size

mm

 90

 90

 120

 120

 120

 180

 180

 180

 180

Weighing chamber height

mm

209

209

209

209

209

Net weight, approx.

kg

5.1

5.1

5.1

5.1

5.1

5.2

5.2

5.2

5.2

Quintix

®

Model

224-1x

1

) 124-1x

1

) 513-1x

1

) 313-1x

1

)

213-1x

1

)

5102-1x

1

) 3102-1x

1

) 2102-1x

1

) 1102-1x

1

)

Accuracy class

k

k

K

K

K

K

K

K

K

Type

2

)

SQP-A

SQP-A

SQP-B

SQP-B

SQP-B

SQP-C

SQP-C

SQP-D

SQP-D

Max

g

220

120

510

310

210

5,100

3,100

2,100

1,100

Scale interval d

mg

0.1

0.1

1

1

1

10

10

10

10

Verification scale interval e

mg

1

1

10

10

10

100

100

100

100

Min

mg

10

10

20

20

20

500

500

500

500

Tare (subtractive)

< 100% of the max. weighing capacity

Typical stabilization time

s

3

2

1.5

1.5

1.5

1.5

1.5

2

2

isoCAL:
– Temperature change
– Time interval


K
h


1.5
4


1.5
4


2
4


2
6


2
6


2
6


2
6


2
6


2
6

Display result
(depending on the set filter level)

s

0.2

0.2

0.1/0.2

0.1/0.2

0.1/0.2

0.1/0.2

0.1/0.2

0.1/0.2

0.1/0.2

Weighing pan size

mm

 90

 90

 120

 120

 120

 180

 180

 180

 180

Weighing chamber height

mm

209

209

209

209

209

Net weight, approx.

kg

4.9

4.9

4.9

4.9

4.9

5.2

5.2

4.7

4.7

Advertising