调整跳线(平均远程感应器读数) changing jumper positions, Averaging readings from remote sensor) – Wine Guardian Through-the-Wall Wine Cellar Cooling Systems 50Hz (WG25) - Manual User Manual

Page 46

Advertising
background image

45

调整跳线(平均远程感应器读数)

Changing Jumper Positions

(Averaging readings from Remote Sensor)

跳线位置

1

Jumper position 1













跳线位置

2

Jumper position 2













跳线位置

3

Jumper position 3


若使用多个远程温/湿度感应器,请参考

图片,根据需要改变感应器主板上的跳线

位置。最多可同时使用三个远程感应器。

If using multiple Remote Temperature/Humidity
sensors in your application, refer to the photos
showing the need to change the jumper locations
internal to the control board on each remote
sensor (up to 3 maximum).

如需平均所有感应器读数,跳线帽必须插在不
同的跳线针上。
For the control to average all of the sensors
utilized (if more than one), the jumper must be in
different positions on the pins.

有三种跳线设置方式。如需跳线,请
There are three pin settings. To access the jumper:

1.拧下感应器塑料封盖上的螺丝,进行跳线设

置。随后系统将依次平均各个感应器上的读
数。跳线失败时,系统将只能读出一个感应
器上的读数,无法计算多个感应器的平均读
数。

1. Remove the two-set screws holding on the

plastic cover. This procedure allows the control
to go to each remote sensor in sequence to
average. Failure to perform this procedure will
result in the system reading only one sensor
and not the average of multiple sensors.

提示:如果使用多个感应器,请将10号设定
项(setting 10)从出厂默认设置调为“平均
读数”。请向Air Innovations服务部门咨询
访问码,进行第8到第10项设定。
NOTE: If multiple sensors control the WG
unit, change factory default in configuration
setting 10 to “averaging.” Obtain access code
from Air Innovations service department to
use in configuration 8 to reach configuration

10.