The Brute Elite 125

6.5 Recognized Chemicals

The following manufacturers offer glycols,

inhibitors, and anti-foamants that are suitable for use

in the Brute Elite. Please refer to the manufacturers

instructions for proper selection and application.

1. Sentinel Performance Solutions Group

2. Hercules Chemical Company

3. Dow Chemical Company

6.6 Hot Water Piping

6.6.1 Domestic Hot Water Piping (BLMC)

Connect domestic hot and cold water piping to the

boiler at locations noted in

Figure 13

. Expected DHW

performance is indicated in

Table 8

.

Use of flow restrictor is optional to prevent colder

water at excessive flow rates. Contact Bradford White

for alternate configurations.

6.6.2 Indirect Water Heater Piping (BLMH)

The BLMH model can control an indirect water

heater zone. Pipe to the locations shown in

Figure 13

.

Zone valve and associated wiring are not required.

Setpoint is made via aquastat located on the indirect

water heater, or can be controlled at the boiler via a

remote sensor.

6.7 Condensate Drain

A condensate drain trap is built into the Brute Elite.

Connect a 3/4” PVC pipe between the drain

connection and a floor drain (or a condensate pump if a

floor drain is not accessible).

The condensate drain must be installed so

as to prevent accumulation of condensate. When

a condensate pump is not used, the tubing must

continuously slope downward toward the drain with no

spiraling.

Consult local codes for the disposal method.

Caution

Condensate is mildly acidic (pH=5), and may harm

some floor drains and/or pipes, particularly those

that are metal. Ensure that the drain, drainpipe,

and anything that will come in contact with the

condensate can withstand the acidity, or neutralize

the condensate before disposal.

Damage caused by

failure to install a neutralizer kit or to adequately

treat condensate will not be the manufacturer’s

responsibility.

Figure 14. Hydronic Piping — Low temp system with indirect water heater (BLMH using internal 3-way).