Bradford White Corp.

SECTION 1.

General Information

1.1 Introduction

This manual provides information necessary for

the installation, operation, and maintenance of Bradford

White Corp. Brute Elite appliances. Read it carefully

before installation.

All application and installation procedures should

be reviewed completely before proceeding with the

installation. Consult the Bradford White Corp. factory,

or local factory representative, with any problems or

questions regarding this equipment. Experience has

shown that most operating problems are caused by

improper installation.

All installations must be made in accordance with

1) American National Standard Z223.1/NFPA54-Latest

Edition “National Fuel Gas Code” or 2) CSA B149.1

“Natural Gas and Propane Installation Code” and with

the requirement of the local utility or other authorities

having jurisdiction. Such applicable requirements take

precedence over the general instructions contained herein.

All electrical wiring is to be done in accordance

with the local codes, or in the absence of local codes,

with: 1) The National Electrical Code ANSI/NFPA No.

70-latest Edition, or 2) CSA STD. C22.1 “Canadian

Electrical Code - Part 1”. This appliance must be

electrically grounded in accordance with these codes.

WARNING

Brute Elite units

must be installed in accordance with

the procedures detailed in this manual, or the Bradford

White Corp. warranty will be voided. The installation

must conform to the requirements of the local

jurisdiction having authority, and, in the United States,

to the latest edition of the National Fuel Gas Code,

ANSI Z223.1/NFPA54. In Canada, the installation must

conform to the latest edition of CSA B149.1 Natural Gas

and Propane Gas Installation Code, and/or local codes.

Where required by the authority having jurisdiction,

the installation of Brute Elite boilers must conform

to the Standard for Controls and Safety Devices for

Automatically Fired Boilers, ANSI/ASME CSD-1. Any

modifications to the boiler, its gas controls, or wiring

may void the warranty. If field conditions require

modifications, consult the factory representative before

initiating such modifications.

1.3 Model Nomenclature

The Model Number is shown on your Rating

Plate and consists of a series of letters and numbers

(nomenclature) that further identifies the characteristics

of your Brute Elite.

The following nomenclature identifies the

individual characters of your model number.

(1-3)

Model Series Designation

B L M = Bradford White, Brute Elite 125

(4)

Usage

H = Modulating Boiler

C = Combination Boiler and Water Heater

(5-7)

Size

1 2 5 = 125,000 BTU/hr input

(8)

Fuel

N = Natural Gas

P = LP Gas

(9)

Altitude

A = 0-10,000 Feet

(10)

Revision

1 = First version

(11)

Options Code

X = No Options

(12)

Pump Options

X = No Pump

Model Nomenclature

1.2 Rating Plate

The Rating Plate contains Manufacture Date, Model

Number, Serial Number, Output Rating, and all other

information pertaining to your Brute Elite. The Rating

Plate is located behind the center panel which will not

open until the lower front panel is opened first.

To open the Brute Elite, first loosen the two

phillips screws (

see Figure 1A

) and then open the front

bottom panel downward. The center front panel will

then also open downward, revealing the Rating Plate.

1.4 Start Up / Shut Down Instructions (Decal)

The Start Up / Shut Down Instruction (Decal) can be

found on the back of the Top Panel (

see Figure 1A

).

This Decal is also referred to as the Operating Instructions

Label and/or Warning Label.

2

3

4

5

6

7

8

9

10

11

12

L M

1 2 5

A

1

X

X

SERIES

B L M

USAGE

H - HYDRONIC
C - COMBI
UNIT

SIZE

MBTU/h

1 2 5

FUEL

N - NATURAL
P - PROPANE

ALTITUDE

A - 0-10,000 FEET

REVISION

1 - FIRST

OPTIONS

X - NONE

PUMP

X - NONE

B

1