Connection of proximity switches

The following proximity switch combinations can be connected:

}

A: pnp, B: pnp

}

A: npn, B: npn

}

A: pnp, B: npn

}

A: npn, B: pnp

When connecting proximity switches please note:

}

Proximity switches can either be connected to terminals In1, In2 and GND or to tracks

A and B plus GND on the RJ45 socket.

}

Track S should be used to monitor the supply voltage (see drawing). A permitted volt-

age range can be entered in the menu.

}

Connect the proximity switch to 24 VDC of the power supply.

}

When connecting the proximity switches, please refer to the chapter entitled

"EMC-compliant wiring"

}

Invalid signals may occur with cable lengths >50 m. In this case we recommend that

you connect a resistor between the signal lines, as shown in the diagrams.

IN2

IN1

GND

24 V

0 V

INI_A

INI_B

RJ45

A

/A

B

/B

Z

/Z

GND

S

pnp proximity switch with resistor R = 10 kOhm

npn proximity switch with resistor R = 47 kOhm