Open circuit message
If an open circuit error is detected, the "Fault" LED lights up on the device, the outputs are
switched off and an error message appears on the display.
The error message is continually updated. It will be displayed until the error is rectified.
The outputs will not switch back on until all the start-up conditions are met.

Error message

Description

Remedy

Error
Signal:
A/A B/B Z/Z

No feasible signal at

one or more tracks

- Ensure that there is no open circuit

in the wiring of tracks A... /Z
- Ensure that the correct encoder is

configured and connected
- Ensure that the encoder operates

correctly.

Frequency difference message on proximity switch
If a frequency difference error is detected, the "Fault" LED lights up on the device and a
warning message appears on the display: "AB frequency deviation".
The warning message disappears automatically once valid signals are again present for
both proximity switches. The Fault LED also goes out.
If the warning message appears, it will no longer be possible to carry out configured fre-
quency range monitoring. The output or outputs will react as if the configured range has
been violated.
If the frequency difference is present for an extended period, without a valid signal, greater
than the global standstill frequency, from the two proximity switches, error message 6000
will appear (see "Current error messages"), all outputs will switch off and the Fault LED will
light up.
The error message disappears automatically if

}

Valid signals, greater than the global standstill frequency, are detected from both prox-

imity switches

or

}

A falling edge is detected at start input S34

The outputs will not switch back on until all the start-up conditions are met.

Warning message

Description

Remedy

AB frequency
deviation

Frequency of the prox-

imity switch at track A

differs from the frequen-

cy of the proximity

switch at track B for too

long and by too much.

- Ensure that the proximity switches

operate correctly
- Check whether a proximity switch

constantly switches due to the

drive's edge jitter.