Input Device

A

/A

B

/B

X6

PNOZ s30

Drive

Adapter

GND

GND

1

8

Connection of proximity switch and rotary encoder

When connecting the rotary encoders and proximity switches, please refer to the chapter
entitled "EMC-compliant wiring".
Encoder types:

}

Configuration: HTL single Z Freq. Ini pnp

– HTL single ended (A,B) + Ini pnp (Z)
– HTL single ended (A,B) + HTL differential (A as Z)
– HTL single ended (A,B) + HTL single ended (A as Z)

}

Configuration: TTL single Z Freq. Ini pnp

– TTL single ended (A,B) + Ini pnp (Z)
– TTL single ended (A,B) + HTL differential (A as Z)
– TTL single ended (A,B) + HTL single ended (A as Z)

Please note:
Tracks /A, /B and /Z must remain free.

24 V

0 V

X6

PNOZ s30

2

4

7

A

B

GND

Input Device

3

1