6 information – Pilz PNOZ s30 24-240VACDC 2 n/o 2 n/c User Manual

Page 55

Advertising
background image

Commissioning

Operating Manual PNOZ s30
1001715-EN-13

55

Information

Level Menu designation

Description

Display/Settings

1

System Time

Time that the device is switched

on

xxx.xxx h
xx min xx s

1

Max. Speed
Track AB

Max. measured linear/rotational

speed at tracks A and B
The value can be reset to 0

0 … 4.29 MHz
or the corresponding value in the set

unit
Reset:
Reset: YES?

1

Max. Speed
Track Z

Max. measured linear/rotational

speed at track Z
The value can be reset to 0

0 … 4.29 MHz
or the corresponding value in the set unit
Reset:
Reset: YES?

1

Relay (Ctrl, 1, 2)
Cycles

Information:
Total number of relay operations
Relay Ctrl (root relay, common 2nd

shutdown route)
Relay 1 (relay output 1: 11-12, 13-

14)
Relay 2 (relay output 2: 21-22, 23-

24)

0 ... 6.000.000 x, > 6.000.000 x

1

CRC of
Configuration

Check sum of configuration pa-

rameters

0 ... 65535

1

Error Stack Entries Error stack entries

Up to 20 error stack entries are

displayed
Repairable errors: Level 2, 3 and 4
(can be rectified by user)
System errors: Level 2 and 3
(internal error, information for Pilz

Service).
See section entitled "Error stack

entries"

Repairable error:
Level 2:
1. Line: Seq. No. "Err.:", error number
2.+3. Line: Plain text to describe error

for the user
Level 3:
1. Line: Seq. No. "repairable"
2. Line: "System time:"
3. Line: System time when the error oc-

curred
Level 4:
Information for Pilz Service

System errors:
Level 2:
1. Line: Seq. No. "Err.:", error number
2. Line: "System Error"
3. Line: System time when the error oc-

curred
Level 3:
Information for Pilz Service

6.2.6.6