Safety-related architecture

Sensor

proximity switch

Actuator

SRP/CS

Actuator

SRP/CS

Sensor

PNOZ s30

Logic

+

Diagnostic

SRP/CS

Logic

Sensor

proximity switch

To calculate the safety function you will need the following data for the "sensor" subsystem
and "PNOZ s30" subsystem:

Sensor

PNOZ s30 subsystem

Category MTTFd

DC

Operating mode

PFH (1/h)

4

Manufactur-

er-specific

90 % Monitoring

2 encoders

1,44E-09

In a worst case scenario, the sensor subsystem's characteristic value MTTFd is calculated
from the inferior (lower) value of the two sensors.

Achievable safety level

Safety function

PL in accordance with EN

ISO 13849-1: 2006

SIL CL in accordance with

EN IEC 62061

Direction
Position

-

-

Speed
Speed range
Standstill

PL e (Cat.4)

3

Please note:
Common cause failures (CCF) are possible for the sensor subsystem. An appropriate anal-
ysis must be carried out.
To use proximity switches 1 and 2 we recommend that you:

}

Use different technologies/design or physical principles (e.g. different manufacturers)

and

}

Evaluate the encoder supply via track S