3 configure speed monitor, 4 password protection, Configure speed monitor – Pilz PNOZ s30 24-240VACDC 2 n/o 2 n/c User Manual

Page 40: Password protection

Advertising
background image

Commissioning

Operating Manual PNOZ s30
1001715-EN-13

40

Configure Speed Monitor

The settings are made via the rotary knob, as follows:
Press the knob

}

Confirm selection/setting

}

Switch to menu

Rotate knob

}

Select menu level

}

Set the parameter/numeric value

The speed with which you turn the knob affects the sequence of the menu and numeric val-
ues:

}

Slowly: Units

}

Quickly: Tens

}

Very quickly:

– Setting the numeric value: Hundreds
– When switching the menu level: Jump to

ESCAPE

CAUTION!
Please note that all parameters are set to their default values on delivery.
Please check all the safety-related parameters at least, and enter the values
that correspond to your application.

Information
If no value is set or amended within 30 s of a menu action, the display re-
verts to the default display. The current setting remains unchanged.
If the master password has been entered, this time increases to 5 minutes.

Password protection

The configuration is protected through passwords. There is a master password and a cus-
tomer password.
Factory setting for both passwords: 0000
The password levels contain different authorisations:

}

Master password

Display: All settings

Edit: All settings

6.2.3

6.2.4

Advertising
This manual is related to the following products: