Safety-related characteristic data for operation with a safe rotary

encoder

Safe encoders are certified in accordance with EN 61508, EN 13849 and EN 62061. In or-
der to achieve the safety level stated by the encoder, the safe evaluation device (PNOZ
s30) must normally detect designated errors. Details of the safe encoder's requirements of
the evaluation device can be found in the user documentation for the safe encoder. The en-
coder and evaluation device must be compatible.

Permitted encoder types and output signals
Permitted encoder types:

}

Rotary safe encoder

}

Linear safe encoder

Permitted output signals:

}

Sin/Cos output signals 1Vss, reference voltage

}

Sin/Cos output signals 1Vss, differential

Safety-related architecture

Sensor

safe encoder

Actuator

SRP/CS

Actuator

SRP/CS

Sensor

PNOZ s30

Logic

+

Diagnostic

SRP/CS

Logic

To calculate the safety function you will need the following data for the "sensor" subsystem
and "PNOZ s30" subsystem:

Sensor

PNOZ s30 subsystem

PL

SIL

PFH

(1/h)

Operating mode

PFH (1/h)

See manufacturer

Monitoring

Safe encoder

2,78E-09

Achievable safety level

Safety function

PL in accordance with EN

ISO 13849-1: 2006

SIL CL in accordance with

EN IEC 62061

Speed
Speed range
Direction
Standstill
Position

PL e (Cat.4)

3

9.2.6

9.2.6.1

9.2.6.2

9.2.6.3