Advanced settings

Level Menu designation

Description

Settings

1

Positions
Parameter

Settings for position monitoring

functions

2

Position (1 ... 4)
Window width
Default:
1 Imp

Enter width of position window for

position monitoring functions 1 ... 4

1 ... 24.900.000 Imp
or the corresponding value in the se-

lected unit

1

Direction
Parameter

Settings for direction monitoring

2

(Direct. left
max. right,
Direct. right
max. left)
Default:
0 Imp

Enter max. tolerated number of

pulses (or Edg, m, rot) in the

wrong direction.

1 ... 24.900.000 Imp
or the corresponding value in the se-

lected unit

1

Mode
Select Input
Default:
none

Setting for using the select inputs

- All 16
- 1 from 4
- None

1

Select Input
Delay
Default:
tdI: 0 ms

Enter delay time of the select in-

puts Y10 – Y13
Info: The states of the select inputs

are only adopted if they were un-

changed during the set time.

0 ... 30.0 s

1

Function
Hysteresis

2

(F1 ... F9) Function
Hysteresis
Default:
1 %

Enter hysteresis for the switch

functions F1 ... F9
(not effective with position and di-

rection monitoring)

0 ... 50 %

1

Output
Delay

Setting for the delay effect and de-

lay time for the outputs

2

Delay
Output
(Rel.1 ... Out 4)
Default:
On 0 ms (display

only)

Setting for the delay time effect

and delay time for the respective

output

6.2.6.5