3 connection, 2 incremental encoder connection, 1 features – Pilz PNOZ s30 24-240VACDC 2 n/o 2 n/c User Manual

Page 84: Incremental encoder connection

Advertising
background image

Supplementary data

Operating Manual PNOZ s30
1001715-EN-13

84

Connection

L+

L-

K1

K2

23

21

13

11

Y13

A2

22

24

14

S11 S21 S34

12

A1

IN2

IN1

Y1

Y2

GND

Y35 Y34

Y12 Y11

Y33

Y10

Y32

Y30

Y31

K1

K2

S3

F1

pnp

pnp

PNOZ s30

33

S11 S21 Y32 42

S12

13

A1

S22 S34

23

41

A2

14

24

34

PNOZ s4

Incremental encoder connection

Features
PNOZ s30

}

Speed monitoring:

Monitoring for overspeed for the operating modes "Setup" and "Automatic", which are
selected with the switch S1.
– The operating mode "Setup" is selected if the select input SEL1 is activated. Over-

speed is detected during setup at >= 50 Hz and the output Rel. 2 switches off.

– The operating mode "Automatic" is selected if the select input SEL2 is activated.

Overspeed is detected during automatic mode at >= 3000 Hz and the output Rel. 2
switches off.

– If a speed of 2800 Hz is exceeded, the semiconductor output Out1 switches in auto-

matic mode and a message (advance warning) is output via the PLC.