1 permitted encoder types and output signals, 2 safety-related architecture – Pilz PNOZ s30 24-240VACDC 2 n/o 2 n/c User Manual

Page 79

Advertising
background image

Supplementary data

Operating Manual PNOZ s30
1001715-EN-13

79

Safety-related characteristic data for operation with a safe rotary

encoder with Z index

Safe encoders are certified in accordance with EN 61508, EN 13849 and EN 62061. In or-
der to achieve the safety level stated by the encoder, the safe evaluation device (PNOZ
s30) must normally detect designated errors. Details of the safe encoder's requirements of
the evaluation device can be found in the user documentation for the safe encoder. The en-
coder and evaluation device must be compatible.

Permitted encoder types and output signals
Permitted encoder types:

}

Rotary safe encoder

}

Linear safe encoder

Permitted output signals:

}

Square output signals TTL, differential with Z index

}

Square output signals HTL, differential with Z index

}

Sin/Cos output signals 1Vss, reference voltage with Z index

}

Sin/Cos output signals 1Vss, differential with Z index

Safety-related architecture

Sensor

safe encoder with

track Z

Actuator

SRP/CS

Actuator

SRP/CS

Sensor

PNOZ s30

Logic

+

Diagnostic

SRP/CS

Logic

To calculate the safety function you will need the following data for the "sensor" subsystem
and "PNOZ s30" subsystem:

Sensor

PNOZ s30 subsystem

PL

SIL

PFH

(1/h)

Operating mode

PFH (1/h)

See manufacturer

Monitoring

2 encoders

1,44E-09

9.2.7

9.2.7.1

9.2.7.2

Advertising
This manual is related to the following products: