Cleveland Range inverter User Manual

Page 10

Advertising
background image

4

Control Method

V/F Control

Frequency Setting Resolution

Digital Reference: 0.01 Hz (Below 100 Hz), 0.1 Hz (Over 100 Hz)
Analog Reference: 0.03 Hz / 50 Hz

Frequency Accuracy

Digital: 0.01 % of Max. Output Frequency, Analog: 0.1 % of Max. Output Frequency

V/F Ratio

Linear, Square Patter, User V/F

Overload Capacity

150 % of Rated Current for 1 Min. (Characteristic is inversely Proportional to Time)

CO

NTRO

L

Torque Boost

Manual Torque Boost (0 ~ 15 %), Auto Torque Boost

Operation Method

Key / Terminal / Communication Operation

Frequency Setting

Analog: 0 ~ 10V / 4 ~ 20 mA Digital: Keypad

Start Signal

Forward, Reverse

Multi-Step Speed

Up to 8 Speeds Can Be Set (Use Multi-Function Terminal)

Multi Step Accel/Decel Time

0 ~ 9,999 sec, Up to 4 Types Can Be Set and Selected for Each Setting (Use Multi-
Function Terminal), Accel/Decel Pattern: Linear Pattern, U Pattern, S Pattern

Emergency Stop

Interrupts the Output of Inverter

Jog

Jog Operation

Input Sign

al

Fault Reset

Reset Faults When Protective Function is Active

Operating Status

Frequency Level Detection, Overload Alarm, Stalling, Over Voltage, Under Voltage,
Inverter Overheating, Running, Stop, Constant Speed, Speed Searching

Fault Output

Contact Output (A, C, B) – AC250V 1A, DC30V 1A

Output S

ignal

Indicator

Choose One From Output Frequency, Output Current, Output Voltage, DC Voltage
(Output Voltage: 0 ~ 10V)

O

PERATIO

N

Operation Function

DC Braking, Frequency Limit, Frequency Jump, Second Function, Slip
Compensation, Reverse Rotation Prevention, Auto Restart, PID Control

Inverter Trip

Over Voltage, Under Voltage, Over Current, Inverter Overheating, Motor Over
heating, Input/Output Phase Loss, Overload Protection, Communication Error, Loss
of Speed Command, Hardware Fault

Inverter Alarm

Stall Prevention, Overload Alarm

Protectio

n

Momentary Power Loss

Less than 15 msec: Continuous Operation,
More than 15 msec: Auto Restart (Programmable)

Operation Information

Output Frequency, Output Current, Output Voltage, Frequency Value Setting,
Operating Speed, DC Voltage

D

ispla

y

Keypad

Trip Information

Indicates Fault when Protection Function Activated, Memorizes Up to 5 Faults

Ambient Temperature

-10 °C ~ 40 °C (14 °F ~ 104 °F),

CE Certification: 41 °F ~ 104 °F (5 °C ~ 40 °C)

Storage Temperature

-20 °C ~ 65 °C (-4 °F ~ 149 °F)

Ambient Humidity

Less Than 90 % RH Max. (Non-Condensing),

CE Certification: 5 ~85% (Non-Condensing)

Altitude / Vibration

Below 1,000 m · Below 5.9m/sec² (=0.6g)

Application Site

No Corrosive Gas, Combustible Gas, Oil Mist, or Dust

Environ

m

ent

Atmospheric Pressure

70 ~ 106kPa

Cooling Method

Forced Air Cooling

4

4

‘Self-cooling’ for model SV004ACtionMaster -4, SV008ACtionMaster -4.

Advertising