Chapter 4 - Parameter Description [FU2]

58

FU2-71: Accel/Decel Time Scale





This is used to change the time scale.




Setting Range

Select Display

Description

0.01 sec

0

The Accel/Decel time is changed by 0.01

second. The maximum setting range is
600 seconds.

0.1 sec

1

The Accel/Decel time is changed by 0.1

second. The maximum setting range is
6000 seconds.

1 sec

2

The Accel/Decel time is changed by 1

second. The maximum setting range is
60000 seconds.


FU2-72: Power On Display





This code selects the parameter to be displayed
first on keypad (DRV-00) when the power is
turned on.

Setting

Range

Description

0

DRV-00 [Command Frequency]

1

DRV-01 [Acceleration Time]

2

DRV-02 [Deceleration Time]

3

DRV-03 [Drive Mode]

4

DRV-04 [Frequency Mode]

5

DRV-05 [Step Frequency 1]

6

DRV-06 [Step Frequency 2]

7

DRV-07 [Step Frequency 3]

8

DRV-08 [Output Current]

9

DRV-09 [Motor Speed]

10

DRV-10 [DC link Voltage]

11

DRV-11 [User Display selected in FU2-73]

12

DRV-12 [Fault Display]

13

DRV-13 [Motor Direction]


FU2-73: User Display Selection





This code selects the kind of display to be
displayed in code DRV-11.

Setting range

Select Display

Description

Voltage

0

Displays the output voltage of inverter.

Watt

1

Displays the output power of inverter.

Torque

2

Displays the output torque of inverter.

Note: The display of ‘Watt’ and ‘Torque’ is approximate value.




FU2-74: Gain for Motor Speed Display





This code is used to change the motor speed
display to rotating speed (r/min) or mechanical
speed (m/min). The display is calculated by
following equation.

Rotating speed = 120 x F / P, where F=Output frequency, P= motor
pole number

Mechanical speed = Rotating speed x Motor RPM Display Gain







Related Functions: DRV-01, DRV-02 [Accel/Decel Time]

FU2-70 [Reference Freq. for Accel/Decel]

I/O-25 ~ I/O-38 [1

st

~ 7

th

Accel/Decel Time]

Related Functions: DRV-11 [User Display]

Related Functions: DRV-00 [Output Frequency]

DRV-09 [Motor Speed]

FU2-31 [Number of Motor Pole]

Advertising