Chapter 3 - Parameter List

30

Code

Description

Keypad

Display

Setting Range

Units

Factory

Default

Adj.

During

Run

Page

0 (No)
1 (All Groups)
2 (DRV)
3 (FU1)
4 (FU2)

FU2-93 Initialize Parameters

H 93

5 (I/O)

-

0 (No)

No 60

FU2-94 Parameter Write Protection

H 94

0 to 255

18

1

0

Yes

60

FU2-99 Return Code

rt

- -

Yes

60


3.4 Input/Output Group [I/O]

Code

Description

Keypad

Display

Setting Range

Units

Factory

Default

Adj.

During

Run

Page

I/O-00 Jump to Desired Code #

I 0

1 to 99

1

1

Yes

62

I/O-01

Filtering Time Constant for V1
Signal Input

I 1

0 to 9999 [ms]

1 100

[ms]

Yes

I/O-02 V1 Input Minimum Voltage

I 2

0 to I/O-04

0.01 0.00

[V] Yes

I/O-03

Frequency corresponding to V1
Input Minimum Voltage

I 3

0 to FU1-20

0.01 0.00

[Hz] Yes

I/O-04 V1 Input Maximum Voltage

I 4

(I/O-02) to 12.00 [V]

0.01 10.00

[V] Yes

I/O-05

Frequency corresponding to V1
Input Maximum Voltage

I 5

0.00 to (FU1-20)

0.01

50 / 60 [Hz]

Yes

62

I/O-06

Filtering Time Constant for I Signal
Input

I 6

0 to 9,999 [ms]

1 100

[ms]

Yes

I/O-07 I Input Minimum Current

I 7

0.00 to (I/O-09)

0.01 4.00

[mA] Yes

I/O-08

Frequency corresponding to I Input
Minimum Current

I 8

0.00 to (FU1-20)

0.01 0.00

[Hz] Yes

I/O-09 I Input Maximum Current

I 9

(I/O-07) to 24.00[mA]

0.01 20.00

[mA] Yes

I/O-10

Frequency corresponding to I Input
Maximum Current

I 10

0.00 to (FU1-20)

0.01

50 /60 [Hz]

Yes

62

0 (None)
1 (Half of x1)

I/O-11 Criteria for Analog Input Signal Loss

I 11

2 (Below x1)

-

0 (No)

Yes 63

0 (Speed-L)
1 (Speed-M)

I/O-12 Multi-function Input Terminal ‘P1’

Define

I 12

2 (Speed-H)

-

0 (Speed-L)

No 64

18

This function is used to lock the parameters from being changed. Keypad displays “U 0” when the parameters are unlocked and “L 0” when

locked. The lock and unlock code is ‘12’.