Chapter 5 - MODBUS-RTU Communication

80

Negative Acknowledge Response

NAK

Drive No.

CMD

Error Code

SUM

EOT

15h

“01” ~ “1F”

“X”

“**”

“XX”

04h

1 byte

2 bytes

1 byte

2 bytes

2 bytes

1 byte

Total byte = 9 bytes

Action Request for Monitor Registration: Request for read of address registered by monitor
registration.

ENQ

Drive No.

CMD

SUM

EOT

05h

“01” ~ “1F”

“Y”

“XX”

04h

1 byte

2 bytes

1 byte

2 bytes

1 byte

Total byte = 7 bytes


Acknowledge

Response

ACK

Drive

CMD

Data

SUM

EOT

06h

“01” ~

“Y”

“XXXX

“XX” 04h

1 byte

2 bytes

1 byte

n * 4

2 bytes

1 byte

Total byte= 7 + n * 4 = max. 39 bytes


Negative Acknowledge Response

NAK

Drive

CMD

Error

SUM

EOT

15h

“01” ~

“Y” “**” “XX” 04h

1 byte

2 bytes

1 byte

2 bytes

2 bytes

1 byte

Total byte = 9 bytes

Error Code

Error Code

Description

SE Sum

Error

FE Frame

Error

FC

Frame Error (Command): Not in use

FS Frame

Error

(Size)

EE

Parameter EEP Access Error