4 operating, 5 communication protocol (modbus-rtu) – Cleveland Range inverter User Manual

Page 82

Advertising
background image

Chapter 5 - MODBUS-RTU Communication

76

5.4 Operating


5.4.1 Operating

Steps

- Check whether the computer and the inverter are connected correctly.
- Turn ON the inverter. But, do not connect the load until stable communication between the computer

and the inverter is verified.

- Start the operating program for the inverter from the computer.
- Operate the inverter using the operating program for the inverter.
- Refer to “6. Troubleshooting” if the communication is not operating normally.

User program or the “DriveView” program supplied from CMC Industrial Systems can be used as the
operating program for the inverter if I/O-50 [Communication Protocol Selection] was set to default
value 0.

5.5 Communication Protocol (Modbus-RTU)

The communication structure is that the ACtionMaster drives are slaves and a computer/host is the
master.

5.5.1 Supported Function Code

Function Code

Name

0x03

Read Hold Register

0x04

Read Input Register

0x06

Preset Single Register

0x10

Preset Multiple Register


5.5.2 Exception

Code

Exception Code

Name

0x01

ILLEGAL FUNCTION

0x02

ILLEGAL DATA ADDRESS

0x03

ILLEGAL DATA VALUE

0x06

SLAVE DEVICE BUSY


5.5.3 Baud

Rate

1200, 2400, 4800, 9600, 19200bps (default value of 9600bps)