Chapter 3 - parameter list, 1 drive group [drv – Cleveland Range inverter User Manual

Page 30

Advertising
background image

24

CHAPTER 3 - PARAMETER LIST

3.1 Drive Group [DRV]

Code

Description

Keypad

Display

Setting Range

Units

Factory

Default

Adj.

During

Run

Page

DRV-00

Output Frequency during running,
Reference Frequency during stop

0.00

0.00 to (FU1-20)

0.01

00.00 [Hz]

Yes

34

DRV-01 Acceleration Time

ACC

0.0 to 999.9 [sec]

0.1

10.0 [sec]

Yes

34

DRV-02 Deceleration Time

DEC

0.0 to 999.9 [sec]

0.1

20.0 [sec]

Yes

34

0 (keypad)
1 (Fx/Rx-1)
2 (Fx/Rx-2)

DRV-03

Drive Mode
(Run/Stop Method)

Drv

3 (RS485)

-

1 (Fx/Rx-1)

No 35

0 [Keypad-1]
1 (Keypad-2)
2 (V1)
3 (I)
4 (V1+I)

DRV-04

Frequency Mode
(Freq. Setting Method)

Frq

5 (RS485)

-

0 [Keypad-1] No 35

DRV-05 Step Frequency 1

St1

10.00 [Hz]

DRV-06 Step Frequency 2

St2

20.00 [Hz]

DRV-07 Step Frequency 3

St3

0.00 to (FU1-20)

0.01

30.00 [Hz]

Yes 36

DRV-08 Output Current

Cur

* [A]

-

- [A]

-

36

DRV-09 Motor Speed

RPM

* [rpm]

-

- [rpm]

-

36

DRV-10 DC link Voltage

DCL

* [V]

-

- [V]

-

37

DRV-11 User Display Selection

vOL,
Por,

tOr

Selected in FU2-73
(User disp)

- - -

37

DRV-12 Fault Display

nOn -

-

None

nOn

- 37

F (Forward)

DRV-13 Motor Direction Set

drc

r (Reverse)

-

F (Forward)

Yes 37

DRV-20 FU1 Group Selection

FU1

38

DRV-21 FU2 Group Selection

FU2

38

DRV-22 I/O Group Selection

I O

38

Advertising