Chapter 4 - Parameter Description [FU2]

60

The 1

st

functions are applied if the multifunction terminal is not

defined to ‘2nd Func’ or if it is not ON. The 2

nd

function

parameters are applied when the multifunction input terminal
set to ‘2nd Func’ is ON. Parameters not listed on the table
above are applied to the 2

nd

motor as to the 1

st

motor.

Exchange the motor connection from the 1

st

motor to the 2

nd

motor or the opposite when the motor is stopped. Over voltage
or over current fault can occur when the motor connection is
exchanged during operation.

The ‘User V/F’ function of FU1-29 [V/F Pattern] is used for

both the 1

st

motor and the 2

nd

motor.


FU2-91: Parameter Read
FU2-92: Parameter Write









This is useful for programming multiple inverters
to have same parameter settings. The keypad can
read (upload) the parameter settings from the
inverter memory and can write (download) them
to other inverters.










FU2-93: Parameter Initialize




This is used to initialize parameters back to the
factory default values. Each parameter group can
be initialized separately.

Setting Range

Select Display

Description

No

0

Displayed after initializing
parameters.

All Groups

1

All parameter groups are initialized to
factory default value.

DRV

2

Only Drive group is initialized.

FU1

3

Only Function 1 group is initialized.

FU2

4

Only Function 2 group is initialized.

I/O

5

Only Input/Output group is initialized.


Note: FU1-30 ~ FU1-37 [Motor Parameters] must be set first

after initializing parameters.


FU2-94: Parameter Write Protection





This function is used to lock the parameters from
being changed.
The lock and unlock code is ‘12’. Keypad displays
“U 0” when unlocked and “L 0” when locked.

FU2-99: Return Code





This code is used to exit a group. Press [FUNC]
key to exit.



Related Functions: FU1-99 [Return Code]

I/O-99 [Return Code]