ClearOne comm CONVERGE SR 1212 User Manual

Page 114

Advertising
background image

109

of the mute, Cleareffect, and alC buttons, which toggle their respective functions and have no user-configurable
settings, clicking a channel configuration button displays the Channel property Configuration window as shown
below.

the window contains three tabs: NC (Noise Cancellation), Telco Settings, and Telco meters, which are
described in the following sections.

NC (Noise Cancellation) Tab

select the Enable Noise Canceller checkbox to enable nC for the channel. adjust the Cancellation depth
slider to the dB setting which provides the best combination of low noise and maximum speech clarity. the
attenuation depth can be set in 1dB increments from 6dB to 15dB. the default is 6dB. the default for nC is off.

you can use noise cancellation on all types of input channels. see NC (Noise Cancellation) for more information.

Advertising
This manual is related to the following products: