ClearOne comm CONVERGE SR 1212 User Manual

Page 272

Advertising
background image

267

RxBSTEN – Receive Boost Enable

this command selects/reports the receive boost status.

Command Form

: DEVICE RxBSTEN <Channel> [value]

Argument Type

Size

Values

units

Channel

Channel

1

see Groups and Channels

group

group

1

17 (r)

value

unsigned Integer

2

0 = off
1 = on
2 = toggle
(null to query in text)

SERECHO – Serial Echo

this command selects/reports the serial echo of the rs-232 port.

Command Form

: DEVICE SERECHO [value]

Argument Type

Size

Values

units

value

unsigned Integer

4

0 = off
1 = on
2 = toggle
(null to query in text)

NOTE: the unit will return the updated state of the last selection in the same form as the

command.

SFTymuTE – Safety Mute

this command selects/reports the state of the safety mute. safety mute holds all outputs in a muted state. It used
for syncing to a site document to avoid feedback or blown speakers until the unit is in a settled state.

Command Form

: DEVICE SFTymuTE [value]

Argument Type

Size

Values

units

value

Channel

4

0 = off
1 = on
2 = toggle
(null to query in text)

SIGGEN – Signal Generator

this command selects/reports of the signal generator activation.

Command Form

: DEVICE SIGGEN [Channel group type amplitude Frequency]

Argument

Type

Size

Values

units

Channel

Channel

1

see Groups and Channels
(null to query in text)

group

group

1

1, 3, 7 (I, m, l)

type

unsigned Integer

2

1 = pink noise
2 = White noise
3 = tone

amplitude

signed Float

4

-60.00 – 20.00

dB

Frequency

unsigned Float

4

type 1 – 2

0 (null in text)

hz

type 3

20.00 – 20000.00

SIGGENEN – Signal Generator Enable

this command selects/reports of the signal generator activation.

Command Form

: DEVICE SIGGENEN [value]

Argument

Type

Size

Values

units

value

unsigned Integer

4

0 = off
1 = on
2 = toggle
(null to query in text)

Advertising
This manual is related to the following products: