Comtrol PortVision DX User Manual

Page 123

Advertising
background image

PortVision DX User Guide

Uploading the Web User Interface on Multiple RocketLinx Switches

Use this procedure to load the latest web user interface on several RocketLinx switches. You can
only load firmware on multiple switches if they are all of the same model, since the web user
interface is model-specific.

Note: Do not use this procedure to upload Bootloader. Technical Support does not

recommend uploading Bootloader on multiple RocketLinx switches.

1.

Make sure that you have

downloaded the latest firmware

version.

2.

Shift-click the RocketLinx switches for which you want to update and use one of the
following methods:

Click the Upload button

Right-click and then click Advanced and then Upload Firmware

Click Advanced and then Upload Firmware on the Manage menu

3.

Browse to the firmware .bin file and then click Open.

4.

Click Yes to the Upload Firmware message that warns you that this is a sensitive
process.

5.

It may take a few moments for the firmware to upload onto the RocketLinx. The
RocketLinx reboots itself during the upload process.

6.

Click Ok to the advisory message about waiting to use the RocketLinx until the status
reads ON-LINE. In the next polling cycle, PortVision DX updates the Device List pane
and displays the firmware version.

7.

You can use the CD that shipped with your product for installation procedures or use the

appropriate User Guide

to complete the RocketLinx configuration process.

Firmware - RocketLinx

123