Off-line devices, Contacting technical support – Comtrol PortVision DX User Manual

Page 155

Advertising
background image

PortVision DX User Guide

The RocketLinx flashes the SYS LED for five seconds.

2. If necessary, you may need to click Tracker and ON several times to catch the flashing

SYS LED.

OFF-LINE Devices

The Device List may display OFF-LINE device status for a variety of reasons. You may want to
click Refresh to see if the device displays ON-LINE.

Note: Remember, unmanaged RocketLinx switches and other hardware can be toggled

from ON-LINE to OFF-LINE using the General tab of the Properties screen.
PortVision DX can only determine whether a Comtrol Ethernet attached product is
on-line or off-line.

• The device is not powered.

• The device is in the process of booting up and may show as

ON-LINE

at the next PortVision

DX request.

• The device has not completed loading firmware. If possible, check the status LED on the

Comtrol Ethernet attached product.

• A firewall is blocking communications between the device and PortVision DX.

• The device is using the same IP address as another device. If this is the case, an asterisk is

displayed behind the IP address in the Device List pane.

• Incorrect IP addressing in the device has been implemented.

• The device is getting an IP address from a DHCP server so the address is different than

what PortVision DX knows.

• A DeviceMaster is using LOCAL as the Detection Type but it is on the other side of a router

or switch that has Layer 2 MAC mode disabled and only supports Layer 3. If this is the case,
simply

change the Detection Type

from LOCAL to REMOTE.

• The device is too busy to respond to the PortVision DX request for status.

• The device’s Ethernet cable is disconnected or connect into the wrong Ethernet port.

The DeviceMaster 2E/4/8/16-port models with external power supplies follow the IEEE
specifications for standard Ethernet 10/100BASE-TX topologies.

When using the UP and DOWN ports, the DeviceMaster 2E/4/8/16 is classified as a switch.
When using the UP port only, it is a simple end node device. The maximum number of daisy-
chained DeviceMaster 2E/4/8/16 units, and the maximum distance between units is based on
the Ethernet standards and will be determined by your own environment and the conformity of
your network to these standards.

Contacting Technical Support

You can contact Comtrol by calling +1.763.957.6000 (8AM to 6PM CST/USA).

Optionally, you can refer to the

Support web page

or the

Comtrol forum

for more information.