FT-11(D) Technical Manual, Rev. 1.35 November 2010

Page 25 of 52

[014 X] Data Length and Parity

0 : 8 bit, no parity

1 : 7 bit, odd parity

2 : 7 bit, even parity

[015 X] Checksum

0 : Checksum byte disabled

1 : Checksum byte enabled

[02-] Serial Interface 3

The parameters of the 3

rd

serial interface.

[020 X ] Data Format
0 : No output

1 : Continuous data output

2 : Print mode (refer to parameter [040])

3 : Host mode

4 : Modbus RTU High-Low

5 : Modbus RTU Low-High

[021 X] Baud Rate

0 : 1 200 Baud

1 : 2 400 Baud

2 : 4 800 Baud

0 : 1 200 Baud

4 : 19 200 Baud

5 : 38 400 Baud

6 : 57 600 Baud

[022 X] Handshake

0 : No Handshake

1 : Xon/Xoff

[023 XX] Address

The address range is 1 to 99. If you enter 0, the indicator will operate without an address.

[024 X] Serial Mode

0 : Interface operates as RS232C (param. [012] ≠ 2)

1 : Interface operates as RS485

2 : Interface operates as 20 mA TTY Current Loop (not for 12 V DC powered instruments)

[025 X] Data Length and Parity

0 : 8 bit, no parity

1 : 7 bit, odd parity

2 : 7 bit, even parity

Note:

The parameter [025] must be set to “0” for Modbus RTU output.

[026 X] Checksum

0 : Checksum byte disabled

1 : Checksum byte enabled

[04-] Printer

If one of the serial interfaces is selected as printer, the label settings will be made in this sub-block.

[040 X ] Print Out Format

1 : Single line

2 : Multi line

[042 X] Transfer of CN (Consecutive no.) via serial interface

0 : no

1 : yes

[045 ] Minimum Print

[XXXXXX]

If the weight is less than the value entered here, the data will not be printed

[046

X] Print Control

0 : Printing with key

1 : Auto print

2 : Print interlock

Explanation:

If set to “Auto print”, the data will automatically be printed when the value is stable and

higher than the minimum print value. The weight value should fall below the minimum print value to
reprint. If this parameter is set to “Print interlock”, after printing the weight must change for reprint.

[047 XY] Line Feed

X = 0, 1, 2…9

Number of empty lines at the top of the label (numerical key entry)

Y = 0, 1, 2…9

Number of empty lines at the bottom of the label (numerical key entry)

[048

X] Form Feed

0 : No FF

1 : After printing the printer will go to the next page automatically

[049

X] Quantity of Copies

X = 0, 1, 2…9

Number of labels to print for each weighing

Note:

This function is only valid for parameter [040] = 2.