Ethernet option (for ft-11 only), Electrical connections – Flintec FT-11D User Manual

Page 26

Advertising
background image

FT-11(D) Technical Manual, Rev. 1.35 November 2010

Page 26 of 52

8.3. Ethernet Option (for FT-11 only)

FT-1x series indicators which are equipped with an Ethernet option can be connected to Ethernet TCP/IP or
Modbus RTU over Ethernet networks as described below.

8.3.1. Electrical

Connections

The pin configuration of the RJ45 Ethernet connector is described below:

Pin no.

Signal

Description

1

TX+

Differential Ethernet transmit data +

2

TX–

Differential Ethernet transmit data –

3

RX+

Differential Ethernet receive data +

4

Not used, terminated

5

Not used, terminated

6

RX–

Differential Ethernet receive data –

7

Not used, terminated

8

Not used, terminated

1

2

1

2

1: Link LED

2 Activity LED

Shield

Chassis

ground

State

Link LED

Activity LED

Off

No link

No Activity

Amber

10 Mbit/s

Half Duplex

Green

100 Mbit/s

Full Duplex

Connection to an Ethernet hub

Cabling is done using a standard
RJ-45 patch cable.

Direct connection to a PC

Cabling is done using a RJ-45
cross over cable.

8.3.2. Setup

There are several setup parameters for the Ethernet network as described below:

Host Name

Device name on the network. Default is “ “

IP Address

The numeric code that identifies all computers that are connected to the internet.
Default is “92.168.16.250”

Local Port

Ethernet connection point of the device. Default is “10001”

Gateway

Network point that acts as an entrance to other networks. Default is “192.168.16.254”

Subnet Mask

Defines a range of IP addresses in a network. Default is “255.255.255.0”

Primary DNS

Primary DNS server IP address

Secondary DNS

Secondary DNS server IP address

DHCP

The Dynamic Host Configuration Protocol provides dynamically allocated IP
addresses to computers on a network, if it is enabled.

Remote
Connection

Automatic connection to any device on the network

Remote IP

IP address of the PC or device which should be connected automatically

Remote Port

Ethernet connection point of the PC or device which should be connected
automatically


Important hint:

During the setup the Ethernet output (weight value and status bits) will not be updated.