Ft-11 input – Flintec FT-11D User Manual

Page 48

Advertising
background image

FT-11(D) Technical Manual, Rev. 1.35 November 2010

Page 48 of 52

Any input to FT-11 is in two double words and according to the table below.

FT-11 Input

D31M

SB

D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16

Bit no.

D15 D14 D13 D12

D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1

D0

LSB

W31

MSB

W30 W29 W28 W27 W26

W25

W24

W23 W22

W21

W20 W19 W18

W17 W16

RxPDO 1

(R_DW1)

W15 W14 W13 W12 W11 W10

W9 W8 W7 W6 W5 W4 W3 W2 W01

W00

LSB

0 0 0 0

SP3

SP2

SP1

0

Zero

Tare

Print

CLR

Select

RxPDO 2

(R_DW2)

Not used


Here R_DW1 provides the value received from the PLC and R_DW2 describes the meaning of this value as
indicated below.

Bit Nr.

RxPDO2 (R_DW2)

Description

31...28

Not used

Always 0

27 Setpoint

3

26 Setpoint

2

25 Setpoint

1

A transition from 0 to1 activates the command. The value of the first and second
word is loaded to the corresponding setpoint.

24 Not

used

Always 0

23 Zero
22 Tare
21 Print
20 Clear

A transition from 0 to1 activates the command.

19...16 Select

0000 Gros

weight

0001 Displayed

weight

0010 Net

weight

0011 Tara

weight

0100

Setpoint 1 (not continuous)

0101

Setpoint 2 (not continuous)

0110

Setpoint 3 (not continuous)

0111

Latest alibi record no. (always 32-bit integer)

1000

Latest alibi gross weight

1001

Latest alibi tare weight

1010

Zero calibration + Calibration status (see table above)

1011

Span calibration + Calibration status (see table above);
First write the calibration weight value in R_DW1

1100 Calibration

status

(see table on page 50)

15...0

Not used

Always 0