Ft-11 input – Flintec FT-11D User Manual

Page 46

Advertising
background image

FT-11(D) Technical Manual, Rev. 1.35 November 2010

Page 46 of 52

Any input to FT-11 is in four words and according to the table below.

FT-11 Input

Bit

no. 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

1

st

Word

W31

MSB

W30 W29 W28 W27 W26 W25

W24 W23 W22 W21 W20 W19 W18 W17

W16

2

nd

Word W15 W14 W13 W12 W11 W10 W9 W8 W7 W6 W5 W4 W3 W2 W1

W0

LSB

3

rd

Word

0

0

0

0

SP3 SP2 SP1

0

Zero Tare Print CLR

Select

4

th

Word

Not in use


Here the first and the second word describe the value received from the PLC and the third word the meaning of
the first two words as indicated below.

Bit no.

3

rd

Word

Description

12-15

Not Used

Always 0

11 Setpoint

3

10 Setpoint

2

9 Setpoint

1

A transition from 0 to 1 activates the command. The value of the first and second word is
loaded to the corresponding setpoint.

8 Not

used Always 0

7 Zero
6 Tare
5 Print
4 Clear

A transition from 0 to 1 activates the command.

3

2

1

0

Select

0000 Gross

Weight

0001 Displayed

Weight

0010 Net

Weight

0011 Tare

Weight

0100

Setpoint 1 (not continuous)

0101

Setpoint 2 (not continuous)

0110

Setpoint 3 (not continuous)

0111

Latest alibi record no. (always 32-bit integer)

1000

Latest alibi gross weight

1001

Latest alibi tare weight

1010

Zero calibration and calibration status (see table above)

1011

Calibrate span and and calibration status (see table above)
First write the calibration weight value in 1

st

and 2

nd

Word

1100

Only calibration status (see table above)

1010

Zero calibration and calibration status (see table above)

1011

Calibrate span and and calibration status (see table above)First
write the calibration weight value in 1

st

and 2

nd

Word

1100

Only calibration status (see table above)

Advertising