Appendix 2: continues output mode data structure – Flintec FT-11D User Manual

Page 38

Advertising
background image

FT-11(D) Technical Manual, Rev. 1.35 November 2010

Page 38 of 52

Appendix 2: Continues Output Mode Data Structure

The format and the definition of the continuous data output is given below.

Status

Indicated

Tare

STX

STA

STB

STC

D5 D4 D3 D2 D1 D0 D5 D4 D3 D2 D1 D0 CR CHK


The definition of the status bytes STA, STB and STC is given below.

Definition Table for Status Byte A

Bits 0, 1 and 2

Bits 3 and 4

Bit 5

Bit 6

Bit 7

0 1 2 Decimal

point 3 4 Increment

size

0 0 0 XXXXOO

1 0

X

1

1 0 0

XXXXXO

0 1

X

2

0 1 0

XXXXXX

1 1

X

5

1 1 0 XXXXX.X

0 0 1 XXXX.XX

1 0 1 XXX.XXX

0 1 1 XX.XXXX

1 1 1 X.XXXXX

Always 1

Always 1

X

Definition Table for Status Byte B

Bit 0

Gross = 0

Net=1

Bit 1

Weight positive = 0

Weight negative=1

Bit 2

Overload = 1

Bit 3

Stable = 0

Unstable =1

Bit 4

Always = 1

Bit 5

Always = 1

Bit 6

Always = 0

Bit 7

x

Definition Table for Status Byte C

Bit 0

Always 0

Bit 1

Always 0

Bit 2

Always 0

Bit 3

Always 0

Bit 4

Always 1

Bit 5

Always 1

Bit 6

Always 0

Bit 7

x

CR =

( D7,D6,D5,D4,D3,D2,D1,D0 ) = ( X, 0, 0, 0, 1, 1, 0, 1 )

CSUM =

0 – ( STX

 STATUS A  .....  CR )

Advertising