System components

The system can monitor up to 40 sensors and may use any of the devices listed
in Table 1.

Table 1: Supported devices

Device

Description

Door/window sensor

(60-670)

For intrusion protection, install door/window sensors on all
ground-floor doors and windows. At a minimum, install then in
the following locations:

All easily accessible exterior doors and windows.

Interior doors leading into the garage.

Doors to areas containing valuables.

Indoor motion sensor

(60-639)

Indoor motion sensors are ideal whenever it is not practical to
install door/window sensors on every opening. Identify areas
where an intruder is likely to walk through. Large areas in an
open floor plan, downstairs family rooms, and hallways are
typical locations for indoor motion sensors. For installations with
pets, use the SAW Pet Immune PIR (60-807).

Outdoor motion sensor

(60-639)

Use outdoor motion sensors to detect motion in a protected
outdoor area. Detected motion in this protected area can sound
chimes.

X10 module*

When the panel is powered using the line carrier power
transformer, the system can work with any of the following
modules:

X10 lamp module (13-403)

X10 appliance module (13-402)

X10 power horn/remote siren module (13-398)

Freeze sensor*

(60-742)

Freeze sensors detect low temperature conditions, which may
indicate a furnace failure. The sensor contains a bimetallic
thermal switch connected to the built-in transmitter. The sensor
transmits an alarm signal to the panel when the surrounding
temperature drops to about 41ºF (5ºC). When the temperature
rises to 50ºF (10ºC), the sensor transmits a restore signal.

Water sensor*

(60-744)

Water sensors detect water leaks and rising water. The detector
is connected to the sensor by an 8-foot cable. Water that
reaches both detector contact points activates the sensor,
causing it to transmit an alarm signal.