Sia system requirements – Interlogix Simon XT Installation Manual User Manual

Page 24

Advertising
background image

18

Simon XT Installation Manual

• Hardwired siren supervision set to on
• Smoke supervision must be set to on

UL 1023 & 985 24-hour backup:

• For 24-hour backup, the total current draw for all connected devices is limited

to 250 mA (during normal standby conditions) using a 1.2 AH battery.

UL 1635 digital alarm communicator system:

• Same as UL 1023 & 985, plus:

The following settings are in addition to UL 1023 and 985 and are required only if
the system is set up for central station reporting.

• Phone mod 1 set to zero or one.
• Automatic phone test set to 001.
• RF timeout set to four hours.
• AC power failure report set to on.
• CPU low battery report set to on.
• Fail to communicate set to on.
• Entry delay plus the dialer delay must not exceed 60 seconds.

SIA system requirements

SIA system requirements are the same as those described for a UL listed basic
system on page 1, plus:

• If multiple annunciation is required, use hardwired siren part no.13-046.

Note: UL requirements take priority over SIA requirements. Entry delay must not
exceed 60 seconds.

SIA setting requirements

Table 7 below describes programming requirements to meet ANSI-SIA CP-01
(

“System programming” on page 36).

Note: Call waiting services should be disabled to prevent interrupting panel
communication to the central monitoring station.

Table 7: SIA setting requirements

Function

Default setting Required setting

Entry delay

30 seconds

30 to 254 seconds

Exit delay

60 seconds

45 to 154 seconds

Dialer delay

30 seconds

14 to 45 seconds

Autoarm

On

On

Unvacated premises

Off

On