Simon XT Installation Manual

37

Function

Default

Description

Duress code

Blank

Use the duress code in place of the master or user code to cause
a silent alarm.

Code length

Four
digits

Codes can be three to six digits long.

Security

Function

Default

Description

Account number

00000

Lets you program up to a 10-character alphanumeric account
number or delete an existing account number by pressing
Disarm. You can enter numerical digits sequentially. To enter
letters (A to F only), use the scroll keys to select A to F, and
then press OK. To select the next digit, press another number
key. When finished, press OK. The CID format only supports
account numbers with letters B through F, or numbers 0 through
9 (or a combination of those letters and numbers).

Downloader
code

12345

Lets you set a unique five-digit code that is required for initiating
Enterprise Downloader sessions. The code must be five digits
long and can range from 00000 to 99999. The downloader code
must match the downloader access code in the Enterprise
account to perform Enterprise sessions.

Phone lock

Off

Prevents resetting of phone/reporting related options when a
memory clear is preformed (on) or resets these options to their
default values when a memory clear is performed (off). The
following are not reset when on: account number, dealer code,
code length, call wait cancel, phone numbers 1 and 2, phone
report modes 1 to 4, phone lock, downloader phone number
downloader code.

Auto arm

On

Determines how long the system protests (announces
open/failed sensors) when attempting to arm with open/failed
sensors, before bypassing these sensors and automatically
arming the rest of the system. The panel protests an arming
attempt when it has not received a restore (close) signal from
sensors learned into restore-specific sensor groups. Sensors
learned into group 26 (fire) cannot be bypassed.

When this option is on, the panel announces all open/failed
sensors repeatedly for four minutes, then automatically
bypasses the open sensors and arms the rest of the system. If a
sensor is opened during the exit delay and then left open, the
panel will go into alarm after the exit delay has expired. This
option must be on for unvacated premises and exit extension to
work correctly.

When the option is off, the panel displays all open/failed
sensors once, then automatically bypasses the open sensors
and arms the rest of the system after the exit delay has expired.
If other sensors are opened during the exit delay, they will also
be bypassed if left open.

If group 13 (instant perimeter) sensors are opened during the
exit delay, the panel goes into immediate alarm.