Activity

Piezo beep response

Arm doors/windows and motion
sensors

Exit delay. Four beeps sound every 5 seconds and four times
per second during the last 10 seconds.

Silent exit. Four beeps sound at the beginning of the exit
delay and four more sound just before the exit delay expires.

Entry delay. Four beeps sound every 5 seconds and four
times per second during the last 10 seconds.

Disarm

One beep.

Chime

Two beeps (when programmed).

Special chime

Three beeps (when programmed).

Trouble beeps

Six beeps every minute. Press Status to stop beeps for 4
hours.

No activity

Twenty beeps every minute for 5 minutes (when
programmed).

Audio verification options

Table 23 below describes the Audio Verification Options menu.

Table 23: Audio Verification Options menu

Function

Default

Description

Audio mode

Off

Determines the audio mode.

1 (Instant) = Panel stays online with central station for an instant
audio session.

2 (Callback) = Panel hangs up and waits for a callback from t he
central station operator before starting an audio session.

Off = No audio verification.

Fire shutdown

Off

Determines whether system fire sirens are silenced during a
two-way audio session (on), or not (off). Beeps sound every 10
seconds while sirens are silenced.

Panic talk

Off

Determines whether the central station operator can talk to the
user during a silent alarm (off), or just listen in on the premises
(on). Silent alarms occur when sensors learned into groups 02
or 03 are tripped, when the duress code is entered, or when the
panel Police button is pressed and the silent panel police panic
option is turned on.

VOX RX gain

06

Determines the receiver gain level during two-way audio
sessions. If the VOX is switching the speaker on when the
central station operator is not talking, lower both this setting and
the VOX mic gain setting. If the VOX is not switching the
speaker on when the central station operator is talking, raise
this setting and lower the VOX mic gain setting. Changing this
setting does not affect speaker volume.