Interlogix Simon XT Installation Manual User Manual

Page 64

Advertising
background image

58

Simon XT Installation Manual

If you press Status and the panel has not heard from all sensors, the displays
shows SN Test Fail or Aborted.

Table 28: Sensor tripping instructions

Sensor

Do this

Door/window

Open the secured door or window.

Freeze

Remove the sensor cover. Apply ice in a plastic bag to the
sensor (for 10 to 15 minutes). Do not allow the sensor to get
wet.

Water

Press a wet rag or wet finger over both of the round, gold-
plated terminals on the underside of the sensor.

Carbon monoxide alarm

Unplug the CO alarm. Plug it back in, wait 5 seconds, then
press the TEST/RESET button until the unit beeps eight
times.

Glassbreak

Trip the glassbreak sensor with an appropriate glassbreak
test tool.

Motion sensor

Avoid the motion sensor field of view for 5 minutes, and then
enter its view.

Rate-of-rise heat detector

Rub your hand together until warm, and then place one hand
on the detector for 30 seconds.

Shock

Tap the glass twice, away from the sensor. Wait at least 10
seconds before testing again.

Smoke

Press and hold the test button until the system sounds
transmission beeps.

Personal help button

Press and hold the appropriate help button until the light
blinks and the panel sounds for at least seven beeps.

Key fob

Press and hold the Lock and Unlock buttons simultaneously
for 3 seconds.

Remote handheld touchpad

Press and hold the two Emergency buttons simultaneously for
3 seconds.

Table 29: Minimum beeps

Type of sensor

Number of beeps

Wireless intrusion sensors

7-8

Wireless smoke and heat sensors

7-8

Wireless environmental/panic buttons

7-8

Hardwired loops

1

Emergency buttons (remote handheld touchpads only)

7-8

4. Press STATUS. The panel displays Sensor Test Ok.

5. If you press STATUS and the panel has not heard from all sensors, the panel

will display

Sn test fail or aborted

.