Simon XT Installation Manual

65

• Make sure the battery is good and installed correctly.
• Check for interference from metal objects. Move or rotate the sensor.
• Move the sensor to a new location.

If a door or window is closed, but the panel announces it is open:

• Be certain the arrow on the magnet and the guide line on the transmitter are

aligned and within ¼ inch of each other.

• The sensor tamper switch may be open (cover off).

If a motion sensor goes off continuously, be sure the sensor is mounted on a
solid surface and the viewing field is free from sources of changing temperature.

If a motion sensor does not respond to motion:

• Make sure the sensor battery is good and installed correctly. Wait 2 minutes

after installing a new battery to test the sensor.

• Adjust the sensor mounting.
• Leave the area for 3 minutes, then retest.
• The environment may be too hot or too cold. Outdoor sensors operate

between 32 and 120ºF (0 and 49ºC).

• Dirt or dust may be causing the problem. Wipe the sensor with a clean, damp

cloth.

Specifications

Power

9 VAC, 60 Hz, 25 VA transformer minimum

Rechargeable battery: 6.0 VDC, 1.2 Ah lead-acid. The battery will last
24 hours with no AC and specified standby load of 250 mA. Maximum
battery charging current is 45 mA. With loss of AC, panel will continue to
operate normally to a minimum of 5.1 VDC.

Radio frequency

319.5 MHz

Storage temperature

-29 to 140ºF (-34 to 60ºC)

Operating temperature

32 to 120ºF (0 to 49ºC)

Maximum humidity

85% relative humidity, noncondensing

Auxiliary power

Unregulated 5.3 to 12.3 VDC, with a maximum of 250 mA

Size (LxWxD)

7 x 5.75 x 2.125 in. (178 x 146 x 54 mm)