Simon XT Installation Manual

49

Function

Default

Description

Voice chime

Off

Determines whether the panel announces the sensor name.

1 = sensor name

2 = loud ding-dong bell

3 = soft ding-dong bell

Off = no sound

Status beeps vol

7

Determines the panel piezo volume level for status sounds
such as arming, trouble, and status beeps. Volume range is 1
(lowest) to 10 (highest).

HW siren sup

Off

Determines whether the panel monitors hardwired sirens for
open conditions (on), or not (off). If this option is turned on,
sirens connected to the panel terminals require an EOL
resistor in the wire circuit. If this option is turned off, EOL
resistors are not required whether sirens are connected or
not.

Speaker volume

8

Determines the volume of voice messages from the panel
speaker. Volume range is 1 (lowest) to 8 (highest).

Silent police
panic

Off

Determines whether pressing the panel police button causes
an audible (off) or silent (on) alarm.

Panel tamper
alarm

Off

Determines whether the panel activates a tamper alarm
anytime the cover is opened (On) or only when the system is
armed (Off).

Alarm report
verify

Off

Determines whether the panel verifies successful alarm
reports to the central station by displaying “

Phone comm

OK”

(on), or not (off).

Piezo beep options

Table 22 below describes piezo beep options.

Table 22: Piezo beep options

Activity

Piezo beep response

Arm doors and windows

Exit delay. Two beeps sound every 5 seconds and two times
per second during the last 10 seconds.

Silent exit. Two beeps sound at the beginning of the exit delay
and two more sound just before the exit delay expires.

Entry delay. Two beeps sound every 5 seconds and two times
per second during the last 10 seconds.

Arm motion sensors

Exit delay. Three beeps sound every 5 seconds and three
times per second during the last 10 seconds.

Silent exit. Three beeps sound at the beginning of the exit
delay and three more sound just before the exit delay expires.

Entry delay. Three beeps sound every 5 seconds and three
times per second during the last 10 seconds.

Advertising