System programming

To enter system programming:

1. Scroll until the display shows System Programming, and then press OK.

The system prompts for an access code.

2. Enter the access code from the codes listed in Table 11 below.

The system displays each entered access code digit as an asterisk.

3. Press OK.

The panel is now in program mode.

Note:

Do not remove the panel power while in program mode.

Table 11: Simon XT programming codes

Code

Description

Dealer code

You can use the dealer code to program all system functions,
including high-security options that are not accessible with the
installer code if it is different from the dealer code. Depending on
how the access code is set, the default dealer access code is
654321, 54321, 4321 (factory default), or 321. This code can be
used for all programming.

Installer code

Depending on how the access code is set, the default installer code
is 654321, 54321, 4321 (factory default), or 321. This code is limited
to changing all but the following: Dealer code, code length,
downloader code, phone lock, phone #1, phone #2, phone 1 report
mode, phone 2 report mode, HW1 function.

Access codes

Function

Default

Description

Dealer code

4321

You can use the dealer code to program all system options,
including high-security options that are not accessible with the
installer code if it is different from the dealer code. Changing the
dealer code to differ from the installer code will prevent the
installer from viewing certain fields.

If you change the dealer code and enter program mode with the
installer code, the installer should no longer be able to see the
following: code length, downloader code, phone lock, phone #1,
phone #2, phone 1 report mode, phone 2 report mode, HW1
function.

Installer code

4321

You can use the installer code to program most installer options,
except for high-security dealer options.

Master code

1234

You can use the master to arm/disarm, enter user programming,
and bypass sensors.

User codes 1 to
8

Blank

You can use the user codes to arm/disarm the system.