Sensors – Interlogix Simon XT Installation Manual User Manual

Page 63

Advertising
background image

Simon XT Installation Manual

57

Arming
level

Description

Indication

1

Disarm the system.

One beep indicates the system is disarmed. The
panel displays and speaks Disarmed. The Disarm
button lights.

2

Arm doors and windows.

Two beeps verify that door/window sensors are
armed. The panel displays

DOORS+WINDOWS

and speaks Doors and Windows On. The
Doors+Windows button lights.

3

Arm motion sensors.

Three beeps verify that motion sensors are
armed. The panel displays

Motions

and

speaks Motions On. The Motions button lights.

4

Arm doors, windows, and motion
sensors.

Four beeps verify that door/window and motion
sensors are armed. The panel displays

DOORS+WINDOWS & MOTIONS

and speaks

Doors and Windows On, Motion On. The
Doors+Windows and Motions buttons light.

Sensors

Test the sensors after all programming is completed and whenever a sensor-
related problem occurs.

Note:

While the sensor test is a valuable installation and service tool, it only tests

sensor operation for the current conditions. You should perform a sensor test
after any change in environment, equipment, or programming.

Notify the central station you will be performing a test prior to starting the test.

To test the sensors:

1. Place all sensors in their secured (no alarm) state.

2. Scroll to Sensor Test options under the System Tests menu, and then press

OK.

The panel will prompt you to trip each sensor one at a time. You may follow
the panel prompting or test the sensors in any order. See the Table 28 on
page 58 for specific instructions on how to trip each sensor type.

Interior sirens sound transmission beeps, and the display identifies the tripped
sensor and the number of RF packets received. The system will continue to
prompt for sensors that have not yet been tested. When all sensors have
been tested, the display shows SN Test Complete Press Status.

3. Press Status.

The display shows Sensor Test OK.