26

Simon XT Installation Manual

3. Disconnect the green and red premises phone jack wires from the Telco block

D and splice them C to the four-conductor cable A black and white (or yellow)
wires. Use weatherproof wire connectors for these splices.

4. Connect the four-conductor cable A green and red wires to the Telco block D

TIP (+) and red to RING (

–) posts.

5. Connect the phone cord E included with the panel to the RJ31X B and the

panel LINE jack.

Figure 8: Full line seizure wiring with RJ-31X

Full line seizure wiring with one premises phone

If a single phone is all that exists on the premises, full line seizure can be
accomplished without an RJ31X (Figure 8 above).

1. Disconnect the phone from the premises phone jack and plug it into the panel

PHONE jack A. This jack is disconnected automatically whenever the panel
reports.