Installation

This section describes how to open the panel for mounting, mount the panel,
connect sirens, connect hardwired contacts, and connect the AC power
transformer.

UL listed installations

Some installations may require configurations dictated by city/state codes,
insurance, or Underwriter’s Laboratories (UL). This section describes the various
component and configuration listings.

Basic system:

• Control panel: backup battery 6 V 1.2 Ah (34-025) (Portalac model #

PE6V1.2)

• Standard class 2, 9 VAC, 3.34 A power transformer (UTC Fire & Security Part

22-153). Alternate transformer for US installations: MG Electronics Model
MGT925, 9 VAC, 25 VA, (UTC Fire & Security Part 22-155).

• Hardwired siren (13-374)

Household burglary alarm system unit (UL 1023), basic system plus the
following:

• Hardwired magnetic contact (13-068 or 13-071) or wireless learn mode

door/window sensor (60-670)

• Panel piezo beeps set to on
• Entry delay set to 45 seconds or less
• Exit delay set to 60 seconds or less
• RF time-out set to 24 hours
• Control panel alarms turned on
• Autoarm set to on
• Siren timeout set to five minutes or more
• Trouble beeps set to on
• RF jam detect set to on
• Hardwired siren supervision set to on
• Exit extension set to off
• Quick exit set to off

Household fire warning system (UL 985), basic system plus the following:

• Wireless smoke sensor 60-848-95 learned into sensor group 26
• Panel piezo beeps turned on
• Control panel alarms set to on
• Siren timeout set to four minutes or more
• Trouble beeps set to on
• RF jam detect set to on