Central station reporting – Interlogix Simon XT Installation Manual User Manual

Page 25

Advertising
background image

Simon XT Installation Manual

19

Function

Default setting Required setting

Call waiting

Off

On if reporting to central station and customer has
call waiting service

Exit extension

On

On

Swinger shutdown

On (one trip)

On (one trip)

Fire alarm verify

Off

On

Duress/panic code

Disabled

Disabled

Cross zone

Disabled

Disabled for zones with high probability of false
alarms.

Table 8 below describes nonprogrammable (hard-coded) system operation, as
required to meet ANSI-SIA CP-01, and is provided only for your reference.

Table 8: Nonprogrammable (hard coded) system operation

Function

Operation

Silent exit

All annunciators disabled

Remote arming exit time and progress
annunciation

All annunciators enabled

Abort annunciation

Enabled

Cancel report annunciation

Enabled

Recent closing

Enabled (two minute window)

Exit error

Enabled

Restoration of power

Panel resumes operation in same arming
state and disregards alarm signals from
sensors for the first 60 seconds after power
restoration

Cancel alarm

Enter code only.

Central station reporting

The panel has been tested with the following central station receivers using SIA
and Contact ID reporting formats:

Note: Before beginning installation, installers must verify compatibility with the
following central station receivers.

• Radionics D6600 central station receiver
• Sur-Gard central station receiver with models SG-DRL2A and SG-CPM2
• CS5000 digital alarm communicator receiver