Chapter 3:

22

Simon XT TableTop Control Panel Installation Manual

Panel connections

The panel has three screw terminals, two telephone connections, and a 9 VAC
plug (Figure 3).

Figure 3: Simon XT TableTop Control Panel terminal connections

Hardwired device terminals

The screw terminals connect sirens, and/or hardwired detectors.

Program sensors and devices before you install them. Follow the instructions in
Sensors on page 35 to add the sensors to panel memory.

HW1 I/O, HW2 In, and HW1&2 DC Out terminals

The HW1 I/O terminal is dual purpose and can be used for either siren or
hardwired contact connections. The HW2 In terminal is an input only.

Interior sirens

From the factory, the HW1 I/O terminal input is set up for interior siren operation
(status and alarm sounds). HW1&2 DC Out provides the positive (+) voltage.