Appendix A:

74

Simon XT TableTop Control Panel Installation Manual

Specifications

Table 35: Simon XT TableTop Control Panel specifications

Requirement

Description

Power

9 VAC, 60 Hz, 25 VA transformer (minimum)

Rechargeable battery: 6.0 VDC, 1.2 Ah lead-acid. The battery will
last 24 hours with no AC and specified standby load of 250 mA.
Maximum battery charging current is 45 mA. With loss of AC
panel will continue to operate normally to a minimum of 5.1 VDC.

Radio frequency

319.5 MHz

Storage temperature range

-29 to140°F (-34 to 60°C)

Operating temperature range 32 to 120°F (0 to 49°C)

Maximum humidity

85% relative humidity, noncondensing

Auxliary power

Unregulated 5.3 to 12.3 VDC, with a maximum of 250 mA

Size (LxWxD)

7 x 5.75 x 2.125 in. (178 x 146 x 54 mm)

SIA system requirements

SIA system requirements are:

• Control panel: backup battery 6 V 1.2 Ah (model # 34-025)
• Standard class 2, 9 VAC, 3.34 A power transformer (model # 22-153)
• Hardwired siren (model # 13-374)

Plus if multiple annunciation is required, use hardwired siren part no.13-046.

SIA setting requirements

Table 36 below describes programming requirements to meet ANSI-SIA CP-01
(see “System programming” on page 37).

Call waiting services should be disabled to prevent interrupting panel
communication to the central monitoring station

Table 36: SIA setting requirements

Function

Programming page
reference

Default setting Required setting

Entry delay

Table 18 on page 48

30 seconds

30 to 240 seconds

Exit delay

Table 18 on page 48

60 seconds

45 to 240 seconds

Dialer delay

Table 13 on page 41

30 seconds

15 to 45 seconds