Function

Default

Description

Ring hang ring

1

Determines when the panel answers a remote phone access or
Enterprise call. Depending on whether an answering machine
exists at the panel location, offsite access to the panel can be
done with a series of phone calls or just one. For offsite access
where an answering machine does not exist, the user or
Enterprise operator simply calls the panel location once and
listens for 10 rings. The panel should answer after the tenth ring.

For offsite access where an answering machine exists, the user or
Enterprise operator must perform the following steps:

Call the panel location.

Let the phone ring once, then hang up.

Wait at least 10 seconds but not more than 40, then call the

panel location again. The panel should answer on the first

ring.

Ring/hang/ring setting number and sequence of rings after which
the panel answers:

1

Ring/hang/ring or ten rings

2

Ring/hang/ring/hang/ring or ten rings

3

Ring/hang/ring/hang/ring/hang/ ring or ten rings

4

Ten rings

5

Ring/hang/ring

6

Ring/hang/ring/hang/ring

7

Ring/hang/ring/hang/ring/hang/ ring

Off Disabled

—no remote (offsite) access

Dial delay

30
seconds

Determines whether the panel delays dialing programmed phone
numbers before sending reports (on).

If Opening (disarming) Reports is on, the panel does not delay
dialing if the system is disarmed before the delay time expires.
The panel dials immediately for both the alarm and opening
report.

Regardless of this option setting, the panel always dials
immediately for fire alarms, AC power failure and low battery
reports.

Call wait code

Off

The call waiting code is dialed by the panel before a phone
number to disable call waiting. Verify that the end-user has call
waiting with his phone service provider before changing this
option from its default.

Caution:

Changing this option from its default without call waiting

will prohibit the panel from calling the central station.

The call waiting code is programmed the same way as a phone
number.

Advertising