Piezo beep options, Audio verification options – Interlogix Simon XT Tabletop Installation Manual User Manual

Page 58

Advertising
background image

Chapter 4:

52

Simon XT TableTop Control Panel Installation Manual

Function

Default Description

Alarm report
verify

Off

This option determines whether the panel verifies successful alarm
reports to the central station by displaying Phone comm is OK (on), or
not (off).

Piezo beep options

Table 22 below provides piezo beep option details.

Table 22: Panel piezo beeps

Activity

Piezo beep response

Arm doors and
windows

Exit delay

—two beeps sound every five seconds and two times per second

during the last ten seconds.

Silent exit

—two beeps sound at the beginning of the exit delay and two more

sound just before the exit delay expires.

Entry delay

—two beeps sound every five seconds and two times per second

during the last ten seconds.

Arm motion
sensors

Exit delay

— three beeps sound every five seconds and three times per second

during the last ten seconds.

Silent exit

— three beeps sound at the beginning of the exit delay and three more

sound just before the exit delay expires.

Entry delay

— three beeps sound every five seconds and three times per second

during the last ten seconds.

Arm
doors/windows
and motion
sensors

Exit delay

— four beeps sound every five seconds and four times per second

during the last ten seconds.

Silent exit

— four beeps sound at the beginning of the exit delay and four more

sound just before the exit delay expires.

Entry delay

— four beeps sound every five seconds and four times per second

during the last ten seconds.

Disarm

One beep

Chime

Two beeps (when programmed)

Special chime

Three beeps (when programmed)

Trouble beeps

Six beeps every minute. Press Status to stop beeps for four hours.

No activity

Twenty beeps every minute for five minutes (when programmed)

Audio verification options

Table 23 on page 53 provides audio verification option details.