Chapter 4:

Simon XT TableTop Control Panel Installation Manual

49

Function

Default Description

RF time-
out

12
hours

Determines the time period the panel must receive at least one
supervisory signal from learned sensors before identifying a sensor failure
and sounding trouble beeps. Any sensor failure is reported immediately
and again at the supervisory time. The timeout can be set from 02 to 36
hours. Entries must be two digits.

Fail-to-
open time

Off

Determines whether the panel sends a fail to open report to a central
station if the system has not been disarmed by the programmed time (on),
or not (off).

System time must be set correctly for this feature to work.

Fail-to-
close time

Off

Determines whether the panel sends a fail to close report to a central
station if the system has not been armed by the programmed time (on), or
not (off).

System time must be set correctly for this feature to work.

Siren time-
out

005
minutes

Determines how long sirens sound alarms if no one is present to disarm
the system. The time can be set from 002 to 254 minutes. When this
feature is turned off, sirens sound alarms until the alarm is canceled
(system is disarmed).

Arm LED
shutdown

Off

Determines whether the panel LEDs (buttons) turn off 30 seconds after
the last button press (on) or remain on for the entire arming period (off).

Unvacated
premises

On

Determines whether the system automatically arms down to level 2 (doors
and windows) if the user arms the system to level 4 (doors, windows, and
motion sensors) without leaving the premises (on), or remains at the
armed level chosen by the user (off).

This feature does not work from a keyfob. Autobypass must be on for this
feature to work.

Smoke
supervisio
n

Off

Determines how often the panel must receive supervisory signals from the
smoke sensors. If this option is on, the panel must receive at least one
supervisory signal from smoke sensors every four hours or it will identify a
sensor failure and sound trouble beeps. If this option is off, the time for
receiving supervisory signals is determined by RF timeout.

Touchpad options

Table 19 below provides touchpad option details.

Table 19: Touchpad options

Function

Default Description

Keyfob no
delay

Off

Determines whether a keyfob arms the system with no delay (on) or not
(off).

When this feature is on, you must disarm the system before entering the
premises, since it is disabling the entry delay. If Remote touchpad arming
is on, keyfobs cannot disarm the system and will cause an alarm upon
entering.